Subroutine to Apply Hydrostatic pressure by Changing water levels

This subroutine is developed to apply Hydrostatic pressure if we have water level history with time,

A sample model Block.inp refers to subroutine Dload.f. The results show the deformation of block for different water levels.

The water level history is given as follows:

Water Level , Time

10.01, 0.0

25.222, 0.5

50.33, 1.0

30.21111, 1.5

15.999, 2.0

Attached are the following files

Block.inp

Dload.f

Job-1.odb

 

Regards

Ankur Agarwal